calculadora de engenharia

Voltage Coefficient (VCR) Error Calculator

VinR1(V)voutR20 VR0VRR(V)dR/R

Como ler o diagrama. The top resistor changes value as the voltage across it rises, so the ratio at 20 kV is not the ratio you measured on the bench. The curve is that drift and dR/R is the error the calculator returns.

A thick film resistor is not the same value at 20 kV as on a bench meter. VCR is quoted in ppm per volt; this turns it into the resistance change and the divider error it causes.

entradas

Consistentes

R1 change
-
Ratio at 0 V
-
Ratio at working V
-
Erro de proporção
-
Output at working V
-

A fórmula

ΔR/R = VCR × V / 1,000,000. Divider ratio = (R1 + R2) / R2; recalculate it with the shifted R1 to get the error.

What the calculator does not include

Selecionando as peças

Where the ratio matters, specify VCR explicitly: the planar thick film range is quoted for precision divider use, tolerance from 0.2%. For matched pairs, send the ratio and the voltage.

Send the calculated values and the duty: request a technical quote, resposta dentro de 6 horas.